Search
FTA offers a comprehensive set of training in fatigue crack growth and fracture toughness testing. Training is available on location at FTA. Please contact us if interested in learning more about our training options.
General Training
FCGR Training
NLFT Training
Topic
- Test Frame Overview
- Fracture Mechanics Test Specimen Overview
- Relationship Between ADwin and Test Controller
- Servohydraulic PIDF Tuning w/ FTA
- Piggybacking Load Cells
- Multiple Calibration Ranges for Load Cells
- Calibrating and Verifying COD Gages, Shepic Gages, and Extensometers
- Compliance and Potential Difference Fundamentals
- Troubleshooting ADwin Connectectivity Issues
- Setup and Use of FTA DCPD System
- Flat Versus Round Hole Clevises
- Determining initial Kmax Levels/Modulus Based on Material
- Configuring Analog Outputs / Inputs in MTS Station Builder
- Updating Data Sampling Rate in MTS FLexTest Controllers
Topic
- Fatigue Crack Growth Fundamentals (E647)
- Variable-Amplitude Fatigue Crack Growth Fundamentals
- ADwin Hardware Connections
- Running in Simulation Mode
- Constant-Amplitude FCGR Testing w / FTA, PD or Compliance
- Threshold Fatigue Crack Growth Testing w / FTA, PD or Compliance
- Variable-Amplitude Fatigue Crack Growth Testing w / FTA
- Dwell Testing, Custom Waveforms and Shapes
- Recording Validation Files
- Custom K, PD, or Compliance Solutions
- FTA Fatigue Crack Growth File Review
- Understanding the LOG File
- Recovering if Operator Fails to Record an IN3 File
- FTA FCGR Analysis
- Post Test Corrections
- Reference Specimen Technique
- Adjusted Compliance Ratio (ACR) w / FTA
- Using the Multi-Monitor Application
- Running tests with The Matrix
- Selecting Optimum Data Acquisition Intervals
- Marker Banding
- Compression Precracking w/ FTA
- Running Multiple Test Segments on One Specimen
- Recording Auxiliary Data
- Sustained Load Crack Growth (da/dt) Testing
- Best Practices for DCPD Testing
- Clevis and Pin Sizing for C(T) Testing
- Surface Crack Testing Including DCPD Precracking
- DCPD Stability Tests
- Evaluating FCGR Validity Requirements
Topic
- FTA FCGR for Precracking
- FTA NLFT Testing Overview
- FTA NLFT Analysis Including Crack Length Measurements
- Performing an E399 Test on a C(T) Specimen
- Performing an E399 Test on a SEN(B) Specimen
- Performing an E1820 Test on a C(T) Specimen
- Performing an E1820 Test on an SEN(B) Specimen
- Determining Loading Rate
- Using a Shepic Gage
- Using a Crack Propagation Gage for Leak Detection
- Recording Auxiliary Data
- Front Face Versus Load for Compliance Specimens
- Stroke Control
- Side Grooves
- Checking Modulus via Unloads
- Data Collection Rates
- Unloading a Specimen After a Test
- Sim Service Testing
- Evaluating Fracture Toughness Validity Requirements